Battery Service

8 of 35


SPECIFIC GRAVITY READINGS
By measuring the specific gravity of the electrolyte, you can tell if the battery is fully charged, requires charging, or must be replaced. It can tell you if the battery is sufficiently charged for a capacity (heavy-load) test. The battery must be at least 75% charged to perform a heavy load test. (The heavy load test will be discussed later). In other words, each cell must have a specific gravity of 1.230 or higher to proceed.


CELL READINGS
PERCENT CHARGED
1.270
100 %
1.230
75%
1.190
50%
1.145
25%
1.100
0%

 

If the battery is less than 75% charged, it must be fully recharged before proceeding. If the battery is 75% or higher proceed to a heavy load test. A battery not sufficiently charged will fail because it is discharged.